| GlowCore A.C., Inc. USA:
800-676-4546 Canada:
888-525-8888 |
|
|
| Products/Services |
|
|
|
| |
|
|
|
| Gas
Fired Boilers Gas Fired Water Heaters |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| For More Information... |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| GB Series "A" Gas Hot Water Boiler |
|
|
| Features |
Efficiency |
|
|
All series unit feature high
A.F.U.E. ratings (Annual |
|
| High
Efficiency |
Fuel Utilization Efficiency)
when properly installed. |
|
| 92 to
94% AFUE |
|
|
| Clean
Burning |
Venting |
|
| Low NOx |
The Boiler is vented using
2"-3" CPVC/PVC pipe |
|
| Sealed
Combustion |
and fitting in accordance with
the installation |
|
| No Open
Flame |
instructions and local
codes. |
|
| Direct
Vent, CPVC Vent Pipe |
|
|
| Wall
Hung or Floor Mounted |
Heat Exchanger |
|
| Full
Access, Easy Service |
Stainless steel heat exchanger
for long life. |
|
|
|
|
|
Combustion Air Blower |
|
|
Direct drive PSC motors are used
with all models. |
|
|
PSC motors have a low starting
torque, and high |
|
|
efficiency. For ease of
service, the entire blower |
|
|
assembly may be removed. |
|
|
|
|
|
Burner Assembly |
|
|
The unique advanced burner
design provides |
|
|
reliable performance and low
pollutant emissions. |
|
|
Burner assembly is constructed
of Incoel Alloy |
|
|
and stainless steel to ensure
long, reliable life. |
|
|
|
|
|
|
| Boiler
Specifications |
|
| Model Number |
GB040A |
GB060A |
GB090A |
GB130A |
GB160A |
|
| Burners (No.) |
1 |
1 |
1 |
1 |
1 |
|
| Electrical Data (Volts/Hz/Ph.) |
115/60/1 |
115/60/1 |
115/60/1 |
115/60/1 |
115/60/1 |
|
| (F.L.A.) |
3.2 amps |
3.2 amps |
3.2 amps |
4.5 amps |
4.5 amps |
|
| Transformer Size (VA) |
40 |
40 |
40 |
40 |
40 |
|
| A.F.U.E %* |
94.1 |
94.1 |
92.6 |
92.6 |
92.5 |
|
| Flue Size (Inches) |
2 |
2 |
2 |
3 |
3 |
|
| Gas Pipe Size (NPT) |
2-Jan |
2-Jan |
2-Jan |
2-Jan |
2-Jan |
|
| Boiler |
Inlet |
1 |
1 |
1 |
1 1/4 |
1 1/4 |
|
| Water |
Outlet (NPT) |
1 |
1 |
1 |
1 1/4 |
1 1/4 |
|
| Weight |
Net (Lbs.) |
104 |
104 |
104 |
167 |
167 |
|
| Shipping |
110 |
110 |
110 |
173 |
173 |
|
|
|
*As tested at AGA Labs at 120ºF and 80ºF return water temperature. |
|
|
| Model |
BOILER RATING BTU/HR. |
|
| Input |
Orifice |
Output+ |
Manifold |
Water |
Pressure Drop |
|
| Size |
Press. "W.C." |
Pump Min. |
Thru Boiler |
|
| |
|
Flow GPM |
Ft./Water |
|
| GB040A |
40,000 |
#38 |
35,520 |
2.5 |
4 |
32.5 |
|
| GB060A |
60,000 |
#30 |
53,400 |
2.5 |
6 |
8 |
|
| GB090A |
90,000 |
#9 |
79,920 |
2.5 |
8 |
13 |
|
| GB130A |
130,000 |
#10 |
115,400 |
2.5 |
12 |
22 |
|
| GB160A |
160,000 |
#1 DMS |
142,100 |
2.5 |
14 |
28 |
|
| |
|
| +As determined by GAMA. |
|
| Heating capacity valid for elevations up to 2,000 feet above sea
level. |
|
| Model |
Cabinet Size In. |
‡*Max. |
*Max. |
|
| Vent |
Intake |
|
| Length |
Air |
|
| Ft. |
Length |
|
| Width |
Depth |
Height |
|
Ft. |
|
| GB040A |
18 |
11 |
36 |
25 |
25 |
|
| GB060A |
18 |
11 |
36 |
25 |
25 |
|
| GB090A |
18 |
11 |
36 |
25 |
25 |
|
| GB130A |
21 1/8 |
11 |
42 1/8 |
30 |
35 |
|
| GB160A |
21 1/8 |
11 |
42 1/8 |
30 |
35 |
|
|
|
| *Lengths are feet plus 6 elbows. |
|
| ‡First ten feet must be CPVC plastic pipe; additional venting
can be PVC. |
|
|
| |
|
| |
|
|
|
|
|
|
|
|
|
|
| For More Information... |
|
| |
|
|
|
|
|
|
|
|
|
|
| GWH Series "A" Volume Hot Water Heater |
|
|
|
|
|
| Features |
Venting |
|
|
The GWH150 is vented using
3" CPVC/PVC |
|
| 94%
Thermal Efficiency |
plastic pipe and fitting in
accordance with the |
|
| Direct
CPVC Vent |
installation instructions and
local codes. |
|
| Sealed
Combustion |
|
|
| Low NOx
- 7.4 PPM |
Heat Exchanger |
|
| Electronic
Ignition |
The heat exchanger is
manufactured form |
|
| Wall
Hung of Floor Mounted |
stainless steel for long
life. |
|
| Compact
Cabinet |
|
|
|
Combustion Air Blower |
|
|
Direct drive PSC motors feature
low starting |
|
|
torque and high
efficiency. For ease of service, |
|
|
the entire blower assembly may
be removed. |
|
|
|
|
|
Burner Assembly |
|
|
The unique burner design
provides reliable |
|
|
performance and low pollutant
emissions. |
|
|
Burner assembly is constructed
of Incoel |
|
|
Alloy to ensure long, reliable
life. |
|
|
|
|
|
| Water Heater Specifications |
Model |
Water Heating Rating Btu/Hour |
| Model No. |
GWH150 |
Input |
Orifice |
Output |
Manifold |
Water |
Press |
| Burners (No.) |
1 |
Size |
Press. "W.C." |
Pump Min. |
Drop |
| Electrical Data (volts, HZ/PH) |
115/60/1 |
|
|
Flow GPM |
Thru |
| (F.L.A.) |
4.5 |
|
|
|
Boiler |
| Transformer Size |
40 |
|
|
|
Ft./Water |
| Thermal Efficiency |
94.17%* |
GWH150 |
150,000 |
#1 DMS |
141,250 |
3 |
14 |
28 |
| Flue Size (inches) |
3 |
|
| Gas Pipe Size (NPT) |
2-Jan |
|
| Boiler |
Inlet |
1 1/4 |
|
| Water |
Outlet |
1 1/4 |
|
| Weight |
Net (lbs.) |
165 |
|
| Shipping
(lbs.) |
170 |
|
| |
|
| *As
determined by tests performed at AGA Laboratory. |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Back |
|
| GlowCore
A.C., Inc. USA: 4007 Platinum Way, Dallas, Texas 75237 |
|
Telephone: 214-330-8852 Fax: 214-330-0650 Email Sales & Marketing
forwarding: gtoth@abbot-suart.com
|
|
|
|
| | Home |
Products/Services | Success Stories | Resource Library | Customer Service |
News | About | |
|
|
| |
|
|
|
|
|
|
|
|
|
|